Network Power Sequencer
Real-time monitoring of input voltage and output current, providing 2 levels of over-voltage and over-current protection functions, divided into sound and light alarm and cut-off protection. Each level of protection voltage and current value is set by users according to their needs, which
maximally ensures the power safety of users' equipment.
SVIP-9608NPS
This intelligent power management unit is designed for centralized control and monitoring of multiple devices across IP networks. Featuring 8 independently controlled power channels, it supports manual, scheduled, and software-based ON/OFF functions with adjustable sequencing. It offers real-time monitoring, dual-level over-voltage and over-current protection, and an emergency mode for immediate power cut-off. Equipped with TCP/IP and RS485 interfaces, LCD status display, password lock, and optional power purification, it is ideal for high-power applications. Housed in a 1U 19-inch rackmount chassis, it's built for professional AV and IT environments.

Universal Network Access & Device Control:
Accessible from any location with an Ethernet port, enabling control over servers and other IP-based network devices.
Intelligent Network Monitoring:
Features self-diagnosis of network faults with real-time display of network and service status.
Centralized Management via Distributed System:
Seamlessly integrates into a distributed system through a network connection. Managed via network management center software, allowing full control and centralized monitoring of all devices in the system.
Emergency Power Control Mode:
Supports an emergency mode that enables immediate ON/OFF control of all power outputs in critical situations.
Manual and Software Power Control:
Each power output channel can be independently turned ON or OFF either manually or via software commands.
Sequential Power Control with Adjustable Timing:
Power channels can be turned ON or OFF in a defined sequence, with configurable timing intervals to prevent current surge and ensure system stability.
Automated Scheduling & Unattended Operation:
Each power port supports programmable timers for scheduled activation and shutdown, enabling fully automated, unattended system operation.
Advanced On/Off Programming with Behaviour Learning:
Features eight-channel power output with editable on/off scheduling, supporting program editing based on an intelligent behaviour learning model.
Independent Control Interface per Channel:
Each channel includes an individual key switch and LED status indicator, offering granular manual control and real-time visual feedback.
Secure User Access with Password Lock:
Equipped with a keyboard password lock to prevent unauthorized access and operational errors.
LCD Status Display:
Integrated LCD screen provides comprehensive information on current power status, input voltage, and output current.
Dual Interface & Open Protocol Support:
Supports TCP/IP network control and RS-485 serial communication. Includes an open protocol for easy integration with third-party control systems.
Comprehensive Device Monitoring & Protection:
Real-time input/output monitoring with dual-level over-voltage and over-current protection. Users can customize protection thresholds, with audible and visual alarms as well as auto shutoff for maximum safety.
Robust Electrical Specifications:
Equipped with a 40A master air switch, eight 10A standard five-hole outlets (optional universal sockets), and a 30A relay control suitable for high-power applications.
Optional Power Conditioning:
Includes an optional 20A power purification filter module to ensure clean and stable power output.
Professional Rack-Mount Design:
Housed in a 19-inch 1U standard chassis with a thickened aluminium alloy front panel, ideal for professional AV, IT, and network infrastructure environments.
Specifications
Power input
AC 110V / AC 220V
Safety Protection
40A Air Switch
Panel Control
8-Channel
Control Interface
RS485 Serial Port
Power Status Display
LCD Screen
Network Delay
Less Than 100ms
Support Protocols
TCP, UDP
Transmission Rate
10/100Mbps
Network Interface
Standard RJ45

WHERE TO USE
Professional AV
installations
By turning devices on or off in a defined sequence with set time intervals, it prevents inrush current surges that can trip breakers or damage sensitive electronics.

IT server racks and data centers
Controlled startup and shutdown extend the lifespan of equipment by avoiding abrupt power fluctuations.

Broadcast and recording studios
Through network control (TCP/IP or RS485), administrators can monitor and control power channels remotely, ensuring real-time system health checks and management.

Classrooms &
Lecture Halls
Provides a one-touch emergency power cut-off for all channels, enhancing safety in critical situations.

Government & Administrative Offices
Allows systems to be powered on/off based on programmed schedules, ideal for unattended operation in conference rooms, control rooms, classrooms, or broadcast studios.

Courtrooms
Connected systems receive power in a controlled order, avoiding voltage spikes or overloads.

Resources
Valuable resources related to Network Power Sequencer, covering learning materials, guides, and tools you can refer to for product knowledge, integration ideas, and system design.